{"id":37,"date":"2016-06-28T10:16:45","date_gmt":"2016-06-28T10:16:45","guid":{"rendered":"http:\/\/www.wer-china.com\/blog\/?p=37"},"modified":"2018-05-16T09:19:05","modified_gmt":"2018-05-16T09:19:05","slug":"17-kinds-of-uv-printer-fault-solutions","status":"publish","type":"post","link":"https:\/\/www.wer-china.com\/blog\/17-kinds-of-uv-printer-fault-solutions\/","title":{"rendered":"17 kinds of UV printer fault solutions"},"content":{"rendered":"<p><a href=\"http:\/\/www.wer-china.com\/a-ruv-uv-flatbed-printer-83.html\"><em>WER-R6090UV Wood Printer<\/em><\/a><\/p>\n<p>1. No power supply<br \/>\nReason: the printer did not open the power supply; If press the emergency stop button; The power switch damage; The input voltage is too low.<\/p>\n<p>The solution: open the power switch; On both sides of the emergency stop button; Try to press the power switch again; Using the multimeter, measure the actual input voltage, check whether it is normal.<\/p>\n<p>2. Printer printhead is not clear<br \/>\nReason: there is air in ink tube; Secondary cartridges has no ink; Negative pressure is too large; Data row line not correctly connected to the control panel; Bad printhead control panel; Bad power panel, amplitude set has problem; Poor printhead.<\/p>\n<p>Solution: with long tube suck out ink, then remove the air with a syringe; Check whether there is level 2nd cartridges and liquid level sensor; To properly connected data row line; Replace the printhead control panel; Replace the power supply board; Check the amplitude set, confirmation screen channel so is no problem; Replace the new printhead.<\/p>\n<p>3. Print no ink<br \/>\nReason: the printhead dirty; There is air in ink tube; Bad printhead; There is too much negative pressure.<\/p>\n<p>Solution: with automatic cleaning system cleaning printhead; With long tube suck out ink, then remove the air with a syringe; Replace the printhead; To recalibrate the negative pressure.<\/p>\n<p>4. Do not meet the correct pressure<br \/>\nReason: the box to protect the printer ink cartridges (secondary) filling the ink; Negative pressure ink cartridge has the ink; Pressure gauge bad; Refill tube with a hole. Bad air regulator.<\/p>\n<p>The solution: to remove ink from protective box; Remove negative pressure inside the ink; Replace the pressure gauge; Check whether all the refill tube with a hole; Replace the air regulator.<\/p>\n<p>5. The UV lamp is not open<br \/>\nReason: the UV lamp is bad; The UV lamp switch fault; The UV lamp on and off between the time is too short; The power cord not connected well.<\/p>\n<p>Solution: replace the UV lamp; Check whether there is the UV lamp fault; When the UV lights off, before open again there will be 3-5 minutes of waiting time; This is a circuit protection; All the power cord and check the printer\uff0cThe UV lamp systems are connected well.<\/p>\n<p>6. Printer configuration of shutter switch properly<br \/>\nReason: printhead panel bad; Shutter switch does not start on the computer; Shutter configuration is bad<\/p>\n<p>Solution: replace the printhead control panel; Check the Settings on the computer; Determine the UV lamp control has been launched; Change the shutter configuration.<\/p>\n<p>7. Ink control includes sound<br \/>\nReason: Don&#8217;t have enough in ink cartridges.<\/p>\n<p>Solution: check the level of ink cartridges and inject enough.<\/p>\n<p>8. Printer tank to quote<br \/>\nReason: printhead heating system does not have enough water cycle.<\/p>\n<p>solution: fill in the tank.<\/p>\n<p>9. Printhead (carriage) met in the process of print media<br \/>\nReason: the distance between the Printhead (carriage) and medium too close; Vacuum pump shut; Vacuum tube set does not match with the media.<\/p>\n<p>Solution: to adjust the printer Printhead (carriage) and the distance between the medium to the 1.0-2.0 mm; Open the vacuum pump switch; For each medium choice adjust vacuum tube to 25%, 50%<br \/>\n, 75% and 100%.<\/p>\n<p>10. In the process of operation, Printhead (carriage) suddenly stopped<br \/>\nReason: the grating feet dirty; A part of the grating ruler is serious scratch; Bad grating ruler; Bad grating encoder; Grating encoder not installed correctly.<\/p>\n<p>The solution: clean with alcohol grating ruler; Change the print grating ruler; Replace the bad grating ruler; Replacement of grating encoder; Rearrange the grating encoder.<\/p>\n<p>11. The Printhead (carriage) does not move<br \/>\nReason: the machine offline; servo motor offline.<\/p>\n<p>The solution: press the green switch connected computers and printers; Turn off the machine, restart the reset motor after 10 seconds.<\/p>\n<p>12. The printer automatic cleaning function does not work<br \/>\nReason: the poor scraping panel; Software failure.<\/p>\n<p>Solution: replace the bad scraping panel; Reinstall the print driver.<\/p>\n<p>13. The printer did not sprayed white ink<br \/>\nReason: in the options TAB in the dialog on the computer, white ink set in the position of &#8220;none&#8221;; The nozzle tube in air; To use white ink loop switch before printing.<\/p>\n<p>Solution: check the options TAB in the dialog box white ink on the computer setting is correct; Through the long work syringe to remove air; 5-10 before printing, open loop switch white ink and make one<br \/>\nLevel cycle and secondary white ink cartridges.<\/p>\n<p>14. The ink is not dry<br \/>\nReason: the UV lamp mode setting is not correct; The UV lamp brightness is not enough; The UV lamp is broken; The shutter lamp did not open.<\/p>\n<p>Solution: check the UV lamp mode; According to the &#8220;high&#8221; key to strengthen the brightness of the UV lamp; Replace the damaged the UV lamp; Check the shutter lamp, to ensure that the shutter lights can work normally.<\/p>\n<p>15. A printer to print a thief<br \/>\nReason: the printhead arrangement is not correct; Print driver update; The parameters in the wrong color dialog.<\/p>\n<p>The solution: to accurately arranged printhead; Install the latest print driver; Check the color parameters dialog box, to ensure correct Settings.<\/p>\n<p>16. printhead control panel without electricity<br \/>\nReason: poor printhead control panel; There is no electricity J18 connector.<\/p>\n<p>Solution: replace the printhead control panel; Check + 41 v and + 24 v power supply, ensure the power supply is normal.<\/p>\n<p>17. Flying ink printer output sample<br \/>\nReason: due to the different media and the electrostatic; Ion fan is turned off.<\/p>\n<p>Solution: make ion fan on the medium for a few seconds to suppress electrostatic generation; Keep the ion fan has been open.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>WER-R6090UV Wood Printer 1. No power supply Reason: the printer did not open the power supply; If press the emergency stop button; The power switch damage; The input voltage is too low. The solution: open the power switch; On both sides of the emergency stop button; Try to press the power switch again; Using the [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":38,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":[],"categories":[20],"tags":[27],"_links":{"self":[{"href":"https:\/\/www.wer-china.com\/blog\/wp-json\/wp\/v2\/posts\/37"}],"collection":[{"href":"https:\/\/www.wer-china.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.wer-china.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.wer-china.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.wer-china.com\/blog\/wp-json\/wp\/v2\/comments?post=37"}],"version-history":[{"count":0,"href":"https:\/\/www.wer-china.com\/blog\/wp-json\/wp\/v2\/posts\/37\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.wer-china.com\/blog\/wp-json\/wp\/v2\/media\/38"}],"wp:attachment":[{"href":"https:\/\/www.wer-china.com\/blog\/wp-json\/wp\/v2\/media?parent=37"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.wer-china.com\/blog\/wp-json\/wp\/v2\/categories?post=37"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.wer-china.com\/blog\/wp-json\/wp\/v2\/tags?post=37"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}