• +86-21-54306275 (Ex 801)
  • sales@wer-china.com

UV printer daily maintenance 6

1, UV flatbed printer droplets
Analysis: inkjet dissipation, placement is wrong, mainly caused by dirt such as cable ageing, nozzle
Solution: cleaning nozzle, replace the nozzle data line

2, UV flatbed printers printing size is wrong
Analysis: step wrong, wrong image size or bezel-set
Solution: adjust the appropriate step value, properly set image size or borders

3, UV flatbed printers typting is not clear
Analysis: the material is too large,spray nozzle distance without calibration
Solution: adjust the car height, recalibrate nozzle

4, UV flatbed printer can’t work
Analysis: RIP cache file accumulation, namely preach the play didn’t start the network connection
Solution: restart print management system, restart the machine control software, control software of network connection must be pressed

5, UV flatbed printers cleaners work
Analysis: vacuum cleaner has not enough force, smudgy dirt, vacuum cleaners suction nozzle tube, suction nozzle is too far away from the nozzle
Solution: replace the vacuum cleaner or a pipe, clean the suction nozzle, adjust the suction nozzle height

Leave a Comment